Fire Alarm Systems Installation and Maintenance
Gent by Honeywell – C TEC – COFEM – Asenware – EST 3
Gent by Honeywell Fire Alarm System
What Does Fire Alarm Mean?
Gent by Honeywell is a brand of fire detection and alarm systems. Gent is a well-established name in the fire safety industry, and Honeywell is a global leader in building technologies. Gent by Honeywell offers a range of products and solutions for fire detection, alarm and notification, and emergency communication systems
Protecting lives and property from the devastating effects of fire is paramount. In this pursuit, the Gent by Honeywell Fire Alarm System stands tall as a trusted partner, offering advanced technology, unparalleled reliability, and comprehensive solutions.
C TEC - FACP CFP Standard 2,4,8 Zone Conventional Fire Alarm Panel
Certified to EN54 parts 2, 4 and 13, C-TEC’s CFP 8 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price.
Supplied in an attractive flush or surface mountable plastic enclosure, it includes eight detector zones, four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays and combined keypad/keyswitch entry.
A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided.
Optional repeaters and relay expansion boards also available. – C TEC
ZAFIR & LYON CONTROL PANEL
The Zafir Algorithmic addressable Control Panel is EN 54-2 and EN 54-4 according to the latest CE Directives/Regulation.
The new development of Zafir control panel, allow integration of all the functionality of an addressable algorithmic system in a reduced-dimension cabinet with capacity up to 452 detectors in 2 loops.
LYON FACP
The algorithmic addressable Control Panel Compact Lyon is EN 54-2 and EN 54-4 standard certified according to the latest CE Directives/Regulation.
- Control panel configurable with 1 or 2 loops.
- Loop capability 99 points.
- All the points are supervised by the control panel, except the loop isolator KABY.
- Capacity for 64 configurable relays per control panel.
- Can hold up to 99 zones per panel.
- Registry with capacity of 4095 events with date and time
Asenware -Two Wire Addressable Fire Alarm Control System
Addressable Fire Alarm Control Panel 1-8 Loop overview:
Addressable Fire Alarm Control Panel 1-8 Loop AW-FP100 are intelligent panel which are carefully designed to make it suitable for most of applications. It can be configured with other panels or control systems. It’s user friendly functionality makes it suitable to program and configure the devices. 7” touchscreen display gives the information for fire alarm, trouble , supervisory and other related information all the time.
Asenware -Conventional Fire Alarm Control System LPCB
4 Zone Fire Alarm Control Panel AW-CFP2166-4-8
The AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detector, bell, manual pull stations, and sprinkler su
EST 3 Edwards Fire Alarm System
FACPs, or fire alarm control panel comprise of electric panels that function as the controlling components of a fire alarm system The FACP panel receives information from environmental sensors designed to detect any changes associated with fire. It also monitors their operational integrity and provides for automatic control of equipment
A fire alarm is a standalone device or a complete network of devices, installed in a building or an area, which gives audible and/or visible warning of an outbreak of fire in that building or area. A fire alarm system could be automatic, semi-automatic or manual. Fire alarm systems are mandatory in buildings, industrial installations, markets, offices, living spaces, public areas and some kinds of transports.
Safeopedia Explains Fire Alarm
Fire alarms are generally audible and/or visible, mechanical or electrical signals or intelligence, indicating a fire incident that requires emergency actions such as fire-fighting, emergency services and evacuation from a building or an affected area.
There are many different types of fire alarms and combinations depending on the location, occupants of the location, noise environment, legal requirements and choices. The types used singularily or in combinations include:
A fire alarm system is comprised of three main stages:
- Detection – manual (at the sighting of flame or smoke and burning smell) or automatic (heat or smoke detectors). There are chances of false alarms with automatic detection
- Signal initiation – manual (pull or push bell electric or manual), semi-automatic (through a system panel that requires manual confirmation) or automatic (there are chances of false alarms)
- Occupant notification – manual, semi-automatic (auto detection, manual confirmation and notification) or automatic (there are chances of false alarms)
Some fire alarms are combined with automatic fire extinguishing systems hence work as occupant notification and evacuation warning signal
Key Components of a Fire Alarm System:
- Control Panel (FACP): The brain of the system, monitoring and controlling all devices.
- Smoke Detectors: Sensors detecting smoke and heat, triggering the alarm.
- Manual Pull Stations: Wall-mounted devices allowing occupants to trigger the alarm.
- Sounders and Strobe Lights: Alerting devices warning of a potential fire.
- Power Supply: Providing energy to the system.
Fire Alarm Installation and Maintenance: Your Shield Against Disaster
Addressable & Conventional Installation & Maintenance Servicing
- Installations
- Repairs
- Servicing
- all Pakistan
Fire alarm installation and maintenance is key to fire safety. The main aspect of fire protection is to prevent fire. However, should a fire occur at your premises, early automatic fire detection is an essential requirement to help you contain the fire. Fire alarm systems provide early warning of a developing emergency situation. This, in turn, can enable safe evacuation of people from your premises.
We can design, supply, install and commission a fire alarm system to suit your needs, all in accordance with current British Standards.
Having a service and maintenance contract in place for your Fire Alarm System is essential for ensuring your system works when you need it most – in an emergency. Regular maintenance visits identify potential problems before they occur and can be supported with a prioritized response if required. contact us for more information.
Fire Alarm Installation and Maintenance: Your Shield Against Disaster
A fire alarm system is your first line of defense against the devastating consequences of fire. By sounding an early warning and alerting occupants, it saves lives and minimizes property damage. However, the effectiveness of your fire alarm system depends on two crucial factors: proper installation and regular maintenance.
SPE Traders Provide Fire Alarm Installation and Maintenance services in Islamabad , Rawalpindi ,Lahore , Karachi , Quetta , Gwadar , Peshawar , Gilgit , Abbottabad, Multan , Faisalabad all over Pakistan contact us